Multifoils: last throw of the dice
I went to London this morning to attend the first ever press conference of the Confederation of Multifoil Manufacturers (CMM), held at the Building Centre. The CMM consists of four members being Actis, YBS, Euroform and IPP who, combined, account for 90% of UK multifoil market.
They put on a 90-minute presentation consisting of four presenters and a short Q&A session in front of an audience of around 30, made up of people working in the multifoil industry and a number of trade journalists.
• Paul Newman, the secretary of the CMM, opened the proceedings and talked a little bit about the challenges facing them; in particular, the August 2006 release of a technical guidance notice from the LABC (Local Authority Building Control) advising against the use of multifoils as standalone products. Newman insisted that multifoils were being held back by old (redundant?) testing methods. He used a graph to show how multifoils had by then captured 6% of the total UK insulation market, up from just 1% in 2002, but this was now expected to fall; the graph suggested 5% in 2007.
• Paul Mitton, Technical Manager of Euroform, then spoke generally about the installation advantages of multifoils, highlighting speed of installation and minimal depth.
• Matthew King, Technical Manager Actis UK followed. He spoke at length about the failings of the guarded hot box (GHB) test used to evaluate conventional insulation and claimed that GHBs only tested for conduction. He claimed that 93% of heat transfer through building fabric was by radiation (a claim later challenged by Roger Bisby) and that somehow GHB testing was not measuring this. This is a controversial view and is disputed by GHB experts such as Ray Williams (not present) of National Physical Laboratories, who has told me that the GHB test doesn’t distinguish between conduction, radiation and convection. King also contested that the GHB measures a temperature difference in a steady state between 10°C and 20°C and that, in reality, temperature differences in the built environment are much larger than this. This was questioned by a lady from the AJ who thought that 20°C would cover all but the most extreme weather events. King further claimed that GHB lab tests do not take into account
- temperature variations which disturb the thermal system
- rain and humidity which influence thermal conductivity
- solar radiation
- wind strength and direction (convection)
- difference in pressure (interior, exterior)
- water and air tightness
- quality of the installation
- ageing of materials.
However, whilst emphasizing that site tests would be more realistic than lab tests, as has been show in the world of acoustics, he did not explain why site tests would bring about improvements over lab tests. In acoustics, elements on site invariably perform worse than they do in lab tests: here we are expected to believe that multifoils perform better on site than they do in GHB lab tests.
King then gave a lengthy exposition of how the in situ tests are carried out and how close attention is paid to ensuring that the controls are fair:
- two roof assemblies are constructed and tested without insulation to see if they are within ±3% of each other, as regards energy used to heat to a pre arranged internal temperature.
- then both assemblies are tested with 200/250mm mineral wool to see if they remain within the ±3% range.
- only then is multifoil placed in one of the roofs to carry out the comparison testing.
Results from the Actis tests have shown that whilst 200mm of mineral wool results in higher than predicted energy use, the Actis multifoil performs far better than the simple R-values derived from GHB testing would suggest. In fact the multifoil matches the results from the 200mm of mineral wool. This will come as no surprise to those who have followed this debate: it is the essential claim made by all multifoil manufacturers and the one disputed by virtually every other insulation manufacturer.
• The last speaker was Prof Nico Hendriks, professor of Building Materials at Eindhoven University of Technology and the Principal of the BDA Test Institution, a third part approval agency. Hendriks has been hired by the CMM to take on the independent testing of multifoils. Basically, he is charged with replicating the famous in-situ tests carried out by Actis and to use the (hopefully) positive results to persuade EOTA (European Organisation of Technical Approval) to grant multifoils an ETA (European Technical Approval), which would enable multifoils to be awarded an equivalent R value and thus to be used in all European territories.
He ran through the methodology that would be employed in carrying out the tests, but he was later questioned in depth on this by Roger Bisby of Professional Builder who noted that they were only planning to test against mineral wool and that in a configuration that would no longer pass UK building regs (basically wool stuffed between rafters). “Why not test against Pu foam instead,” asked Roger. Hendriks appeared to be unaware of the current requirements of Part L, saying that no one built like that in Holland anyway as they mostly used panelised roof sections. He also pointed out that there were both cost and time implications for further comparitive tests. “Why not three roofs, why just two?” went the questioning. “I am sure Kingspan would be willing to help with costs.” This observation met with a good deal of laughter from the audience, rather less from the panel.
I asked what the timescale was for their application to EOTA for an ETA. EOTA is like an umbrella organisation for national bodies, such as our own BBA, which have a remit to test innovative building products. It moves slowly and is still considering whether to even look at this testing programme, let alone pronounce on it. One of the drawbacks of in situ testing is that it takes three months to carry out a winter test and three months to do a summer one as well, and the CMM have already missed this winter as a test time, so the very earliest they could have results before EOTA would be mid-2008. EOTA has to reach a consensus on the matter so it is far from clear what the outcome will be, assuming that Henrdriks’ BDA test outcome is positive for multifoils.
Interestingly, there is a second independent testing station being used by the CMM for their in situ tests to place before EOTA. This was mentioned in passing by Prof Hendriks, without reference to who this might be. Later I discovered that this other test station was none other than our own BM Trada, who of course were the original independent verifiers of the Actis in situ tests back in 1997. Why Hendriks was flown in from Holland when they could have called on BM Trada from up the road remains a mystery. Indeed BM Trada didn’t appear to be present at the event at all. Maybe they are seen as being too close to Actis for comfort.
In the question and answer session that followed, the lady from the Architects Journal asked what the middle layers of radiant foil actually did. Paul Mitton gave a reply that was both convoluted and unintelligible. I report that I am none the wiser!
Another questioner asked about Web Dynamics, a multifoil manufacturer who are conspicuously not members of the CMM, having made a decision that multifoils were best used as a supplementary insulation layer. Web Dynamics have achieved BBA third party approval (a UK-only version of ETA) after testing their multifoil, Thinsulex, in conjunction with conventional insulation materials in the BBA’s guarded hotbox. The CMM speakers were dismissive of the Web Dynamics approach and claimed that their multifoil was an inferior product that couldn’t match the performance of the ones produced by CMM members. Mitton claimed that: “Their wadding is black and as you know black material absorbs heat, not what you want in thermal insulation.”
The last question was about the BRE tests that took place at a site near Aberdeen. These were essentially in situ tests of multifoils against conventional insulation and the results appear to confirm the GHB lab tests – i.e. multifoils do not match the claimed for 200mm of mineral wool insulation. Mathew King’s view was that the test was not as rigorous as the ones that they had carried out, nor as the ones that they want BM Trada and BDA in Eindhoven to undertake.
Over lunch I was able to question Andrew Whittle from IPP and Claire who had flown over from Actis in France. I asked Claire if it was true that Lafarge were in the process of buying Actis: this was news to her, so it appears to be just gossip. I also asked her how Actis sold throughout Europe. She said it was a difficult time for them, as authorities seemed to be closing ranks against multifoils for similar reasons as we are seeing in the UK. Interestingly, they have never been able to sell into Germany (why does that not surprise me?) because the Germans have always insisted on hard R-value figures, which means positive GHB test results. But most other countries have been receptive to multifoils.
In summary, the multifoil industry feels very aggrieved that it has been unable to establish that its products do actually work as they claim. They say that their UK market has been badly affected by the LABC advice to stop using multifoils on their own, but that many metropolitan local authorities are still happy to accept multifoils, especially in loft conversions where it is often virtually impossible to build in the correct depth of insulation using conventional materials. They seem to be pinning their hopes on a) independent testing verifying their own test results and b) consequent EOTA approval, which would give multifoils access to all European markets via an equivalent R value method which even the Germans would have to accept.
My own feeling is that they are being extremely optimistic about their chances. What I didn’t hear today was any convincing explanation as to why multifoils perform so poorly in the guarded hotbox test and yet appear to equal large depths of mineral wool in comparison tests. As happens so often with the multifoil debate, I came away with more questions than answers. It’s all very well carrying out in situ tests, but it’s not altogether clear what exactly is being measured. It may be that 200mm of mineral wool as an insulator is very much worse than the lab tests indicate, in which case the multifoil comparison tests are simply illuminating this point. And why always test against mineral wool? It is rarely used in roof applications these days because it’s hard to meet the requirements of Part L without an absurdly deep rafter. Why not test against more realistic options for today’s housebuilders? And why can’t they come up with a scientifically plausible explanation of the workings of multifoils? Whilst I don’t doubt the sincerity of the multifoil manufacturers, their arguments are still some way short of compelling and on the basis of what they showed us today I really think they have their work cut out if they are to win the approval of EOTA, certainly first time around. It is far more likely that EOTA will ask the same question as Roger Bisby. “Why just test against a roof stuffed with mineral wool? If you want our approval for this unorthodox test procedure, let’s see more tests against a wide range of insulation products.” It could be 2010 before EOTA reaches a conclusion by which time the multifoil industry may well be history.
Labels: Insulation


7 Comments:
I checked your blog for climate change information but ended up reading your piece on multi-foils. Which, having hitherto thought that multifoils were a stack of kites, came as a bit of a suprise. Are you serious that CMM have 5% of a £1 billion market selling a product that all the authorities (ie, everyone else I could read on google) say is being very seriously oversold ? Surely, (and even my cretin american neighbour who thinks that insulation is what you get in a humvee, agrees with me on this) we should be putting in more insulation - not less. It's time Ruth Kelly got stuck into these cowboys.
I checked the Actis website. They say they've been going since 1980. 27 years and no test method anyone believes! Give me a break - they're making it up!.
I typed in ACTIS MULTI-FOILS into Google and came up with ENIGMA INSULATION who seem to be a distributor for ACTIS. I clicked on to TRI ISO SUPER 10 DATA SHEET. It advertises a U value of 0.19 - which presumably is the figure everyone's griping about. Then I clicked on TRI ISO SUPER 10 CERTIFICATION. This brings up the BM TRADA certificate for TRI ISO SUPER 10 which has no U values at all !
Question 1 Why do BM TRADA refuse to put any U value on their own certificate for Actis?
Question 2 Why is everyone talking about the Actis claims if Actis invent the figure themselves anyway?
To follow up question 1 (I suspect that there is no answer to question 2) I checked the LABC Technical Guidance Note (I know, what an inky swot - but it's on the same Google page ) and finally got my head around U and R values (which now hurts - no wonder everyone's confused!) But the bottom line seems to be that if you convert everything into R values there is a general correlation between R values for multi-foils measured in a GHB and in the in-situ tests. That is, that the known R value for a multi-foil is roughly 1.7. On that basis the R value for the glass wool in the BM TRADA test is 1.7 as well.
Maybe this is why BM TRADA kept away from the press conference
And then there's the question of that 5%. £50 million a year can buy a lot of "help" BM TRADA? Building Control? CMM seem to be able to get an amazing amount of business making wild claims in a sector of the market which is meant to be tightly regulated . How?
Steve,
You've asked lots of questions, but you also seem to have got as close as anyone to answering them with the aid of Google, so no need for a lengthy reply.
The multifoil story is quite extraordinary and deserves to be much better known by the general public. But thermal insulation just isn't sexy like polar bears or snowless ski resorts so its details remain buried in obscure blogs.
I'm not so sure about obscure Mark, I bumbled into it without trying too hard - I bet you get tons of traffic. I would not be shocked to learn that you are a google millionaire!
This post has been removed by a blog administrator.
Hi
We are currently involved in a house refurb (ours). We have added a first floor with a warm roof construction above it. On the roofer's recommendation- he has used it on numerous occasions includng his own house with the blessing of the local authority - we have used Actis Super 10. When it snowed recently we lit a wood burning stove under the roof of a "lean to" to keep us warm while we worked in the house. The very high heat from the stove went straight up to the insulation in that little roof. The snow sat on that roof for just the same number of days as the snow on the main roof which had no heat at all underneath it at all, anywhere. This may be unscientific and circumstantial but it must prove something.
A builder I know was very excited by TriIso9 multifoil last year because it seemed so easy to just staple it in sheets to the underside of rafters compared with cutting and fitting Celotex-Kingspan, let alone flat-laying 250mm+ of mineral wool and thereby losing all your storage space. However the latest Installation Guidelines for TriIso10 says you have to have a stationary air gap without ventilation 25-50mm either side of the foil, otherwise the reflective-insulative effect is invalidated. So where's the gain on rafter depth gone now, never mind the difficulty of ensuring real air-tightness, and the extra layers of vapour-controlled plasterboard? From the Guidelines fitting multifoil now looks very fiddly compared with straightforward inserting of Celotex between your rafters and then plasterboarding. I've given up on mineral wool because I hate losing my level loft space for storage. Of course, grants from government or power suppliers are stuck in the dark ages and are only available for flat-lain mineral wool.
To me it seems simple. Build 3 large sheds, small houses. Say 500 square feet. Insulate each one with 3 different types, 1 a multifoil, 2nd with foam board kingspan etc, 3rd mineral wool to their equivalent stated R/U VALUES. Stick an identical C.H. system in, and a digital room stat inside and out. Fire it up and run £50's worth of gas through each one on a meter. Then see how long it lasts. Then Grade them accordingly.
Rather than jiggery pokery and statistics.
You could do one summer, winter and spring? But maybe it wold be the wrong type of weather for the loosers. You do not need to be clever with it. you need to know which is the best, and the best value for money spent. Also, how long it would take to recoup the spending cost against savings over, say 5 years. This is just off the top of my head, so with a bit of thought it could be refined but not too complicated. As i would certainly like to know.